Bluebell Opticom Ltd.

 
BC2x1SW Optical Switch for Diverse Routing pdf

The BC2x1SW is an optical switch designed to offer system designers increased flexibility in their fibre installations. Two separate optical inputs A and B are fed into the single slot
BC Series card.
Internal logic on the card then senses the light levels of the inputs and will switch from a main to reserve path in the event of signal loss. By routing two separate diverse fibres to the A and B inputs automatic switchover will occur in the event of a failure at the upstream transmission point. The sensitivities at which the changeover occurs can be user defined to suit the
installation increasing user confidence.

A BCSPLIT is used upstream to provide a 50:50 optical feed to the separate optical fibres.
Passive splitters can be provided with different ratios of output light levels.

The BC2x1SW occupies a single slot in the BC100-3RU 19" rack-mounting frame which can hold up to 15 single slot cards. Some BC Series processing cards have dual functionality allowing up to 30 channels of video to be transmitted or received from a single 3RU frame.
Signal and card monitoring is achieved through SNMP monitoring in the BM101 network card.
Alternatively GP-Output alarms can be triggered via the BM100 module.

For stand alone applications the BC2x1SW can be housed in an individual rugged enclosure.

Schematic Diagram Rear Panel
schematic End panel
Specifications for each channel
Optical Input
Connector * 1 x female FC/PC, ST or SC
See Ordering Information
Wavelength
1200-1610 nm
Sensitivity > -20 dBm @ 1.485 Mb/s
> -25 dBm @ 270 Mb/s
Max I/P power > -1 dBm
Data rate Transparent
Optical Output
Connector 1 x female FC/PC, ST or SC
See Ordering Information
Wavelength 1310 nm, 1550 nm
See Ordering Information
Optical Power -14 dBm @ 850 nm
-6 dBm @ 1310 nm
-6 dBm @ 1510 nm
General card specifications
Depth: 60 mm
Width: 20 mm 4TE
Height: 100 mm (3RU)
Weight: 100 g
Operating Temp: -30 to +70 ºC
Power: 2.2 W
Signal detect: LED on for loss of signal
No of slots: 1
Conformance
EMI/RFI: Complies with 89/336/EEC
Electrical: Complies with EN 61000-6-1, EN61000-6-2
Laser Safety Complies with Class 1 laser product
24 CFR 1040.10 & 1040.11
RoHS: Complies with Directive 2002/95/EC
Warranty: 5 years
* See Ordering Information
The connector types specified below are supplied as standard.
For alternative connectors please replace the last two suffices of the part
number with the relevant type.
Please contact the Sales Office before ordering.
ST ST connector
FC FC connector
SC SC/PC connector
Ordering Information
BC2x1SW 2 input, 1 output optical switch
The standard connector used is FC/PC. Contact the Sales Office for alternatives.
Universal Chassis and Power Supplies
BC100-3RU 19" 3RU Chassis for up to 15 BCxxx Cards with optional Network Monitoring and
facility for Dual Redundant Power Supplies (not supplied).
BC100-3RU/48V 19" 3RU Chassis for up to 15 BCxxx Cards with optional Network Monitoring and facility
for Dual Redundant Power Supplies (not supplied). Fitted with 48V dc input.
BM100 Network Monitoring Card with GPI Output on a SCSI Connector for Slot-16
BM101 Network Monitoring Card with Ethernet connection for Slot-16
BC140 Extender Card for BC100 3RU Chassis
PS65 90-250VAC Power Supply for BC100-3RU or BB100-3RU Chassis
BB110 Single Slot Chassis with Universal Mains Power Supply
BB120